← Aayan Siddiqui

DC Servomotor Phase-Lead Controller

March 2026 · ELECENG 3CL4 Control Systems · Team of 2. I did the analytical design; my lab partner ran the hardware tests.

The goal was a controller that brings a DC servomotor to 10% overshoot and a 0.3 s settling time. I designed a phase-lead compensator by root locus, checked it in MATLAB, and we tested it on the motor through Simulink.

9.92%overshoot with lead (target 10%)
44.2%overshoot with gain only
339 mssettling time (675 ms gain only)
23.08measured Kv (24.2 predicted)

Design

The plant is G(s) = 31.74 / (s(0.0976s + 1)), with poles at 0 and −10.25.

MATLAB root locus of the compensated system
Root locus of the compensated system in MATLAB. The lead zero at −13.3 pulls the branches left into the target region.

Simulation vs. hardware

In MATLAB the closed loop settled in about 0.266 s, but overshoot came out at 15%. The extra pole and zero make it a third-order system, so the second-order formulas that set the target are only approximate.

On the real motor, the lead compensator gave 9.92% overshoot and settled in about 339 ms. That meets the overshoot spec and lands just over the 300 ms settling target. With gain only, at the same Kc, the motor overshot by 44.2% and took 675 ms to settle.

Hardware step response with the lead compensator
Hardware step response with the lead compensator: 9.92% overshoot.
Hardware step response with gain-only control
The same step with gain only: 44.2% overshoot and visible ringing.

Ramp tracking

A triangle-wave ramp test measured a velocity constant of Kv = 23.08, against 24.2 predicted. That's within 5% of the model.